Success rates in pediatric WPW ablation are improved with 3-dimensional mapping systems compared with fluoroscopy alone: a multicenter study.

Document Type

Article

Publication Date

4-1-2015

Institution/Department

Pediatrics

Journal Title

Journal of cardiovascular electrophysiology

MeSH Headings

Action Potentials, Adolescent, Age Factors, Catheter Ablation, Chi-Square Distribution, Child, Electrocardiography, Electrophysiologic Techniques, Cardiac, Female, Fluoroscopy, Heart Conduction System, Humans, Logistic Models, Male, Multivariate Analysis, Odds Ratio, Predictive Value of Tests, Radiation Dosage, Radiography, Interventional, Recurrence, Retrospective Studies, Risk Factors, Treatment Outcome, United States, Wolff-Parkinson-White Syndrome, Young Adult

Abstract

INTRODUCTION: Three-dimensional mapping (3-D) systems are frequently used for ablation of supraventricular tachycardia. Prior studies have demonstrated radiation dosage reduction with 3-D, but there are no data on whether 3-D improves the efficacy of ablation of Wolff-Parkinson-White syndrome (WPW). We sought to determine if 3-D improves the success rate for ablation of WPW in children.

METHODS: Multicenter retrospective study including patients ≤21 years of age with WPW undergoing ablation from 2008 to 2012. Success rates using the 2 techniques (3-D vs. fluoroscopy alone [FLUORO]) were compared.

RESULTS: Six hundred and fifty-one cases were included (58% male, mean age 13 ± 4 years, 366 [56%] 3-D). Baseline characteristics including gender, weight, accessory pathway (AP) location, number of APs, and repeat ablation attempts were similar between the 2 groups (3-D and FLUORO) The 3-D group was slightly younger (12.7 ± 4.0 vs. 13.3 ± 4.0 years; P = 0.04) and less likely to undergo ablation utilizing cryoenergy (38 [10%] vs. 56 [20%]; P < 0.01). The 3-D group had a higher acute success rate of ablation (355 [97%] vs. 260 [91%]; P < 0.01). No differences were seen in recurrence (16 [5%] vs. 26 [9%]; P = 0.09) or complication rates (1 [0.3%] vs. 1 [0.4%]; P = 0.86) between the groups. On multivariable analysis, 3-D was shown to significantly improve success at ablation with an odds ratio of 3.1 (95% CI 1.44-6.72; P < 0.01).

CONCLUSIONS: Use of 3-D significantly improved success rates for ablation of WPW in children. The increase in acute success associated with 3-D suggests it is an important adjunct for catheter ablation of WPW in children.

ISSN

1540-8167

First Page

412

Last Page

416